SOLAR POWER CABLE, TINNED COPPER CONDUCTOR, XLPO INSULATED AND SHEATHED
GENERAL SCOPE
– It is applied in connection between photovoltaic panels, and photovoltaic panels to the AC inverter, suitable for indoor and outdoor use
STANDARD
- BS EN 50618
- TUV 2 Pfg 1990/05.12
- IEC 60332-1, 2
- IEC 60754-1, 2; IEC 61034-2
IDENTIFICATION
- H1Z2Z2 – K
- Red, black
CONSTRUCTION

TECHNICAL CHARACTERISTICS
- Rated voltage Uo/U: AC: 1,0/1,0 kV | DC: 1,5 kV (max. 1,8 kV)
- Max. conductor temperature for normal operation: 90°C.
- Max. conductor temperature for operation for max 20.000h: 120°C.
- Max. conductor temperature for short-circuit (5s maximum duration): 250°C.
- The fire retardant cables have a significant reduced tendency to propagate fire.
- The cables have low emission of smoke and acid gas when affected by fire.
- The cables must self-extinguish after removing the fire source.
- Weather and UV resistant.
- Resistant to acids and bases.
- Min. bending radius: 5xD (D: overall diameter).